Sign In
Upload
Manuals
Brands
YOKOGAWA Manuals
Test Equipment
CA71 HANDY CAL
YOKOGAWA CA71 HANDY CAL Manuals
Manuals and User Guides for YOKOGAWA CA71 HANDY CAL. We have
2
YOKOGAWA CA71 HANDY CAL manuals available for free PDF download: User Manual
YOKOGAWA CA71 HANDY CAL User Manual (119 pages)
Brand:
YOKOGAWA
| Category:
Test Equipment
| Size: 10 MB
Table of Contents
Introduction
2
Checking Items In The Package
4
Precautions For Safe Use Of The Instrument
7
Précautions D'usage Pour Utiliser L'appareil En Toute Sécurité
11
Table of Contents
15
Functions
18
Names And Functions Of Parts
22
Before Starting Source/Measurement
28
Source
39
Connecting Cables to Terminals
40
Sourcing DC Voltage, DC Current or SINK Current Signal
42
Sourcing DC Voltage or DC Current Signal
42
Ma Function
43
Ma SINK Function
44
Using as 24-V Loop Power Supply
45
Sourcing Resistance or RTD Signal
46
Sourcing Thermocouple (TC) Signals
48
When RJ Sensor Is Used (Making Use of Reference Junction Compensation)
48
When no RJ Sensor Is Used
51
Sourcing Pulse Signals
52
Sourcing a Continuous Pulse Train
52
Sourcing the Preset Number of Pulses (Pulse Cycle)
54
Using the Contact Output
56
Divided Output Function (N/M)
58
Sweep Function
59
Auto Step Function
59
Temperature Monitor Function
60
Measurement
61
Connecting Cables to Terminals
62
Measuring 300 V AC-Range Voltage, DC Voltage, AC Voltage or DC Current
65
Measuring 300 V AC-Range Voltage
65
Measuring DC or AC Voltage
66
Measuring DC Current
66
Measuring Resistance or RTD (CA71 Only) Signal
67
Measuring Temperature with
68
Thermocouple (TC) - CA71 Only
68
Measuring Frequency or Pulses
69
Operating the Calibrator for Frequency
69
Measurement
69
Operating the Calibrator for Measuring Number of
69
Pulses
69
Memory Functions
71
Saving Data into Memory
72
Saving Data in the Order of Memory Numbers
72
Saving Data by Selecting Desired Memory Number
74
Overwriting Data in Memory
74
Reading Data from Memory
75
Clearing Data in Memory
76
Clearing Data by Selecting Desired Memory Number
76
Tip
76
Press the
76
Step 1: Press the
76
Key Once
76
Step 2: Pressing the
76
Whose Data You Want to Read
76
Clearing All In-Memory Data Globally
77
Sending out Data from Memory - CA71 Only
77
Functions Provided By Dip Switch
78
Sweep Function
79
Auto Step Function
81
Selecting the INT RJ Function
83
Selecting the IPTS-68 Function
84
Switch Not Used
84
Temp Switch
84
Selecting the Contact in Function (Contact Input for Pulse Measurement)
84
Communication Function - Ca71 Only
85
Cables Connection and Interface Specifications
85
Setting the Mode
86
Types of Mode
86
The LCD Shows
86
Tip
86
Data Format
87
Data Structure
87
Commands
88
Detailed Description of Commands
89
Troubleshooting And Calibration
96
Method Of Calibrator Adjustment
98
Calibration Standard Selection and Environmental Requirements
98
Adjusting Source Functions
100
Adjusting Measurement Functions
104
Adjusting DC Voltage and DC Current Ranges
104
Adjusting AC Voltage and Resistance
106
(400 Ω) Ranges
106
Notes on the Adjustment of Temperature Ranges
107
CAL71 Only
107
Post-Adjustment Verification
107
Using Accessories
108
Specifications
109
13. Regulations and Sales in Various Countries and Regions
115
Waste Electrical and Electronic Equipment (WEEE)
115
Batteries and Waste Batteries
115
Authorized Representative in the EEA
116
Disposal
116
For the Pollution Control of Electronic and Electrical Products of the People's Republic of China
117
Appendix 1 Reference Junction Compensation
118
Advertisement
YOKOGAWA CA71 HANDY CAL User Manual (110 pages)
Brand:
YOKOGAWA
| Category:
Test Equipment
| Size: 10 MB
Table of Contents
Introduction
2
Checking Items in the Package
4
Precautions for Safe Use of the Instrument
7
Table of Contents
11
1 Functions
14
2 Names and Functions of Parts
18
3 Before Starting Source/Measurement
24
4 Source
33
Connecting Cables to Terminals
34
Sourcing DC Voltage, DC Current or SINK Current Signal
35
Sourcing DC Voltage or DC Current Signal
35
Ma Function
36
Ma SINK Function
37
Using as 24-V Loop Power Supply
38
Sourcing Resistance or RTD Signal
39
Sourcing Thermocouple (TC) Signals
41
When RJ Sensor Is Used (Making Use of Reference Junction Compensation)
41
When no RJ Sensor Is Used
44
Sourcing Pulse Signals
45
Sourcing a Continuous Pulse Train
45
Sourcing the Preset Number of Pulses
47
(Pulse Cycle)
47
Using the Contact Output
49
Divided Output Function (N/M)
51
Sweep Function
52
Auto Step Function
52
Temperature Monitor Function
53
5 Measurement
54
Connecting Cables to Terminals
55
Measuring 300 V AC-Range Voltage, DC Voltage, AC Voltage or DC Current
57
Measuring 300 V AC-Range Voltage
57
Measuring DC or AC Voltage
58
Measuring DC Current
58
Measuring Resistance or RTD (CA71 Only) Signal
59
Measuring Temperature with Thermocouple (TC) - CA71 Only
60
Measuring Frequency or Pulses
61
Operating the Calibrator for Frequency
61
Measurement
61
Operating the Calibrator for Measuring Number of
61
Pulses
61
6 Memory Functions
63
Saving Data into Memory
64
Saving Data in the Order of Memory Numbers
64
Saving Data by Selecting Desired Memory Number
66
Overwriting Data in Memory
66
Reading Data from Memory
67
Clearing Data in Memory
68
Clearing Data by Selecting Desired
68
Memory Number
68
Clearing All In-Memory Data Globally
69
Sending out Data from Memory
69
CA71 Only
69
7 Functions Provided by DIP Switch
70
Sweep Function
71
Auto Step Function
73
Selecting the INT RJ Function
75
Selecting the IPTS-68 Function
76
Switch Not Used
76
Temp Switch
76
Selecting the Contact in Function App
76
(Contact Input for Pulse Measurement)
76
8 Communication Function - CA71 Only
77
Cables Connection and Interface Specifications
77
Setting the Mode
78
Types of Mode
78
Data Format
79
Data Structure
79
Commands
80
Detailed Description of Commands
81
9 Troubleshooting
88
10 Method of Calibrator Adjustment
89
Calibration Standard Selection and Environmental Requirements
89
Adjusting Source Functions
91
Adjusting Measurement Functions
94
Adjusting DC Voltage and DC Current Ranges
94
Adjusting AC Voltage and Resistance
96
(400 Ω) Ranges
96
Notes on the Adjustment of
97
Temperature Ranges - CAL71 Only
97
Post-Adjustment Verification
97
11 Using Accessories
98
12 Specifications
99
13 Sales in each Coutry or Region
105
Disposing the Product
105
How to Replace and Dispose the Batteries
105
Authorized Representative in the EEA
106
For the Pollution Control of Electronic and Electrical Products of the People's Republic of China
107
Appendix 1 Reference Junction Compensation
108
Advertisement
Related Products
YOKOGAWA CA150
YOKOGAWA CA310
YOKOGAWA CA320
YOKOGAWA CA330
YOKOGAWA CA51 HANDY CAL
YOKOGAWA CA700
YOKOGAWA CA500
YOKOGAWA CA550
YOKOGAWA HANDY CAL CA51
YOKOGAWA HANDY CAL CA71
YOKOGAWA Categories
Measuring Instruments
Test Equipment
Transmitter
Controller
Media Converter
More YOKOGAWA Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL