• A = 600 ±20 mV
If the lens aperture is greater than F5.6, adjust the light amount with the shutter.
Procedure
1.
Operate the control panel of MSU, and perform the automatic white balance adjustment.
WHITE button → ON (lit)
After the adjustment is completed, the message "AWB : OK" is displayed.
2.
Make a line selection at the center white portion of the grayscale chart.
3.
Operate the control panel of MSU, and set as follows.
(1) PAINT button → ON (lit)
(2) Touch panel operation: (Page 1) → [Detail] → [3/3]
4.
Adjust the edge at portion B(white) to the desired clip level.
• Adjustment item : [W Limiter]
5.
Adjust the edge at portion C(black) to the desired clip level.
• Adjustment item : [B Limiter]
6.
Store the reference file.
(Refer to the
"5-4-12. File
HDC4300
A
Line selection
C
Store".
B
5-21