Obey the contents of following preparation and procedure, use calibrated equipment and tools.
Preparation
• Setting of MSU
KNEE OFF button → OFF (lit)
• Shoot the full-white pattern so that it is aligned with the under scanned monitor frame.
• Lens iris: F4 to F5.6
• A = 600 ± 20 mV
If the lens aperture is greater than F5.6, adjust the light amount with the shutter.
A
• Lens focus: ∞
• Set the lens extender or shrinker as follows.
Lens extender (x2) → OFF
Lens shrinker (x0.8) → OFF
• Set as follows by camera setup menu.
MENU: OPERATION
PAGE: LENS FILE
ITEM: FILE
1.
Select the file in accordance with the lens attached. If there is no appropriate file, select NO OFFSET.
2.
Change the name of lens with MSU.
Procedure
1.
Operate the control panel of MSU, and perform the automatic white balance adjustment.
WHITE button → ON (lit)
After the adjustment is completed, the message "AWB : OK" is displayed.
2.
Open the following items with using the MSU.
(1) MAINTENANCE button → ON (lit)
(2) Touch panel operation: [Camera] → [White Shading] → [R]
HDC4300
5-14