C h a r g e r 2 D a m p e r S e r v i c e
2 0 0
H o u r S e r v i c e
1
RL: Turn the lockout adjuster knob to the open, unlocked position.
RL:
Turn the lockout adjuster knob to the open, unlocked position.
Remove the knob.
Remove the knob.
2
RL R:
RL R: Remove the cable stop collar. Remove the spool.
Remove the cable stop collar. Remove the spool.
3
Remove the Charger 2 Damper assembly.
Remove the Charger 2 Damper assembly.
Clean the upper tube threads.
Clean the upper tube threads.
C h a r g e r 2 D a m p e r R e m o v a l
RL Unlocked
RL R: 2 mm
RL: Top Cap/Cassette Tool
RL: 2 mm
RL R: 2 mm
RL R: 24 mm
39
Charger 2 Damper Service