CHAPTER 3

3.1 GENERAL

This chapter contains instructions for initial inspection, preparation for use and repackaging for
shipment. Connection to PC, setting the communication port and linking Genesys power supplies
are described in Chapter 7.
The Genesys
Restricted Access Location (RAL). Access to Hazardous
parts (rear side of the power supply) shall be prevented after
installation.
Genesys power supplies generate magnetic fields which
might affect the operation of other instruments. If your
equipment is susceptible to magnetic fields, do not position
it adjacent to the power supply
To avoid electric shock hazard, do not insert conductive parts
.
through the front panel slits.

3.2 PREPARATION FOR USE

I
n order to be operational the power supply must be connected to an appropriate AC source. The
AC source voltage should be within the power supply specification. Do not apply power before
reading, Section 3.6 and 3.7.
Table 3-1 below, describes the basic setup procedure. Follow the instructions in Table 3-1 in the
sequence given to prepare the power supply for use.
Step no.
1
Inspection
2
Installation
3
AC source
4
Test
5
Load connection
6
Default setting

3.3 INITIAL INSPECTION

Prior to shipment this power supply was inspected and found free of mechanical or electrical
defects. Upon unpacking of the power supply, inspect for any damage which may have occured in
transit.
The inspection should confirm that there is no exterior damage to the power supply such as broken
knobs or connectors and that the front panel and meters face are not scratched or cracked. Keep all
packing material until the inspection has been completed. If damage is detected, file a claim with
carrier immediately and notify the Lambda sales or service facility nearest you.

3.4 RACK MOUNTING

TM
The Genesys power supply series is designed to fit in a standard 19" equipment rack.

3.4.1 To install the Power Supply in a rack:

1. Use the front panel rack-mount brackets to install the power supply in the rack.
2. Use a support bar to provide adequate support for the rear of the power supply. Do not obstruct
the air exhaust at the rear panel of the unit.
INSTALLATION
WARNING
TM
series is intended only for installation in
NOTE
TM
WARNING
Item
Initial physical inspection of the power supply
Installing the power supply,
Ensuring adequate ventillation.

AC source requirements

Connecting the power supply to the AC source.
Turn-on checkout procedure.
Wire size selection. Local /Remote sensing.
Single or multiple loads.
The power supply setting at shipment.
Table 3-1: Basic setup procedure
Description
14
14
TM
Reference
Section 3.3
Section 3.4
Section 3.5
Section 3.6
Section 3.7
Section 3.8
Section 3.9
Section 7.2.1

Advertisement

Table of Contents
loading

Table of Contents