Motion Synchronous Actions - Siemens SINUMERIK 840D sl Programming Manual

Job planning
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Significance
The variables only have valid values if machine data $MN_IPO_MAX_LOAD is greater than 0.
Otherwise the variables for both SINUMERIK powerline and solution line systems always
specify the net computing time during which the interrupts caused by HMI are no longer
taken into account. The net computing time results from:
● synchronized action time,
● position control time and
● remaining IPO computing time without interrupts caused by HMI
The system variables always contain the values of the previous IPO cycle.
$AN_IPO_ACT_LOAD
$AN_IPO_MAX_LOAD
$AN_IPO_MIN_LOAD
$AN_IPO_LOAD_PERCENT
$AN_SYNC_ACT_LOAD
$AN_SYNC_MAX_LOAD
$AN_SYNC_TO_IPO
$AC_SYNC_ACT_LOAD
$AC_SYNC_MAX_LOAD
$AC_SYNC_AVERAGE_LOAD average computing time for synchronized actions in the channel
$AN_SERVO_ACT_LOAD
$AN_SERVO_MAX_LOAD
$AN_SERVO_MIN_LOAD
Variable for the overload notification:
The machine data $MN_IPO_MAX_LOAD is used to set the net IPO computing time
(as % of IPO cycle) from which the system variable
$AN_IPO_LOAD_LIMIT will be set to TRUE. If the current load falls below this limit, the
variable is again set to FALSE. If the machine data is 0, the entire diagnostic function is
deactivated.
The evaluation of $AN_IPO_LOAD_LIMIT allows the user to define a strategy for avoiding a
level overflow.
Job Planning
Programming Manual, 06/2009, 6FC5398-2BP20-0BA0
current IPO computing time (incl. synchronized actions of all
channels)
longest IPO computing time (incl. synchronized actions of all
channels)
shortest IPO computing time (incl. synchronized actions of all
channels)
current IPO computing time as percentage of IPO cycle (%)
current computing time for synchronized actions over all
channels
longest computing time for synchronized actions over all
channels
percentage share that the synchronized actions have of the
complete IPO computer time (over all channels)
current computing time for synchronized actions in the channel
longest computing time for synchronized actions in the channel
current computing time of the position controller
longest computing time of the position controller
shortest computing time of the position controller

Motion synchronous actions

10.4 Actions in synchronized actions