1
On Section 1.3 and 9.2
Further information for IQ-Sense
As from Firmware Version V3.0.1 IQ-Sense is supported by the IM 153-2Bx00.
The following supplements result for the function tables:
For Table 1-2
Functions /
Properties
IQ-Sense
For Table 9-2
Functions /
Properties
IQ-Sense
2
On Section 3.5
Further information on redundancy with IM 153-2
You can operate the IM 153-2 redundantly
At an SIMATIC S7-400H (e.g. CPU 417-4H)
With a GSD file at any DP masters (e.g. S5-115H)
In case of configuration with a GSD file, redundant operation of the IM 153-2
can only be carried out in the DPV0 operating mode. Setting of this operating
mode is carried out differently depending on the configuring tool used.
With software redundancy
The optional software "SIMATIC S7 Software Redundancy" is required in
addition to the STEP 7 basic package.
Conforming to standard
Specification System Redundancy (SR) V1.0, Dec. 2001 of the PROFIBUS
user organization
Product Information for Distributed I/O Device ET 200M, Manual
A5E00272208-01
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Interface Module With Order Number 6ES7 ...
153-1AA..
Interface Module With Order Number 6ES7 ...
153-2AA..
153-2BA..
00
01
02
00
x
(as from
firmware
V3.0.1)
153-2Ax..
153-2Bx..
(as from firmware
V3.0.1)
153-2AB..
153-2BB..
(FO)
00
01
x
(FO)
00
x
(as from
firmware
V3.0.1)
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents