Commissioning and Diagnostics
Diagnostic Interrupt of Modules with Digital Outputs
Byte x+4
See Figure 6-11 on page 6-32
:
Byte x+7
7
Byte x+8
7
Byte x+9
7
Byte x+10
7
6
5
4
3
Byte x+11
:
:
Diagnostic event on channel/channel group 7 of the module
6
5
4
3
7
Byte x+12
0
Short-circuit to M
Wire break
External load voltage is missing
Temperature rise
Byte x+13: Assignment for channel/channel group 1 as for byte x+12
Byte x+14: Assignment for channel/channel group 2 as for byte x+12
:
Byte x+19: Assignment for channel/channel group 7 as for byte x+12
Figure 6-13

Structure as of byte x+8 for diagnostic interrupt (digital outputs)

6-34
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
0
72
: Module with digital outputs
H
0
Length of the channel-specific diagnosis
0
Number of channels per module
2
1
0
Diagnostic event on the channel/channel group 0 of the module
Diagnostic event on the channel/channel group 1 of the module
2
1
0
Diagnostic events for channel/channel group 0
Configuration/parameter assignment error
Ground fault
Short circuit to L+