Table 1.5 Clock Selections For E6000 Sh7040 Emulator - Renesas SH7040 Series Supplementary Information

Renesas microcomputer development environment system
Hide thumbs Also See for SH7040 Series:
Table of Contents

Advertisement

For details on the operating voltage and frequency
specifications, refer to the MCU hardware manual.
In the E6000, clock can be selected as shown in table 1.5 by using the Configuration window or
the Clock command.
Select the clock from a range between 4 MHz to the maximum operation frequency φ (MHz) (see
table 1.4). If the input clock and clock divisor is 4 MHz or below, an error will occur.
Table 1.5
Clock Selections for E6000 SH7040 Emulator
Item
Command Name
Input clock
CLOCK
Clock
CLOCK_MODE
multiplication
Clock division
CLOCK_DIVISOR
Note: *The parameter set for clock multiplication is the same parameter set for mode pins MD3 and MD2
on the user system when Target is selected for the parameter of the clock multiplication.
NOTE
Command
Parameter
8MHz
8.25MHz
10MHz
Target
×1
×2
×4
Target*
1
2
4
Configuration
Window Setting
Option name
Parameter
Clock Rate
8MHz
8.25MHz
10MHz
Target
PLL × 1
Clock Mode
PLL × 2
PLL × 4
Target*
Clock Divisor
1
2
4
Notes
Initial value
Initial value at user
system connection
Initial value
Initial value at user
system connection
Initial value
5