Honeywell SmartLine RM60 Handbook page 90

24 ghz non-contact radar (fmcw) level meter
Table of Contents

Advertisement

TECHNICAL DATA
8
Installation conditions
Process connection size
Process connection position
Dimensions and weights
Materials
Housing
Wetted parts, including antenna
Process connection
Gaskets (and O-rings for the
sealed antenna extension option)
Feedthrough
Weather protection (Option)
Process connections
Thread
Flange version
Flange version
Flange version
Flange version
EN 1092-1
ASME B16.5
JIS B2220
Other
90
The nominal diameter (DN) should be equal to or larger than the antenna diameter.
If the nominal diameter (DN) is smaller than the antenna, either:
– provide the means to adapt the device to a larger process connection on the silo
(for example, a plate with a slot), or
– use the same process connection, but remove the antenna from the device before
installation and fit it from inside the silo
Make sure that there are not any obstructions directly below the process
connection for the device.
Refer to "Technical data: Dimensions and weights".
Standard: Polyester-coated aluminium
Option: Stainless steel (1.4404 / 316L)
Horn / Sheet metal horn antenna: Stainless steel (1.4404 / 316L)
Drop antenna: PTFE; PP – a PP or PTFE flange plate protection option is also
available
Stainless steel (1.4404 / 316L) – a PP or PTFE flange plate protection option is also
available for the Drop antenna
PTFE Drop antenna:
PTFE Drop antenna:
PTFE Drop antenna:
PTFE Drop antenna:
FKM/FPM (-40...+150°C / -40...+300°F); Kalrez® 6375 (-20...+150°C / -4...+300°F);
EPDM (-50°C...+150°C / -58...+300°F)
PP Drop antenna:
PP Drop antenna:
PP Drop antenna:
PP Drop antenna:
FKM/FPM (-40...+100°C / -40...+210°F); Kalrez® 6375 (-20...+100°C / -4...+210°F);
EPDM (-40°C...+100°C / -40...+210°F)
Horn / Sheet metal horn antenna:
Horn / Sheet metal horn antenna:
Horn / Sheet metal horn antenna:
Horn / Sheet metal horn antenna:
FKM/FPM (-40...+200°C / -40...+390°F); Kalrez® 6375 (-20...+200°C / -4...+390°F);
EPDM (-50°C...+150°C / -58...+300°F)
Standard: PEI (-50...+200°C / -58...+390°F – max. range. The feedthrough
temperature limits must agree with the temperature limits of the gasket material
and antenna type. If the distance piece option is not attached, the maximum
temperature is 150°C / 300°F.)
Option: Metaglas® (-30...+200°C / -22...+390°F – max. range. The feedthrough
temperature limits must agree with the temperature limits of the gasket material
and antenna type. If the distance piece option is not attached, the maximum
temperature is 150°C / 300°F.)
Stainless steel (1.4301 / 304)
G 1½ (ISO 228); 1½ NPT (ASME B1.20.1)
DN80 in PN40 (Type B1), DN100...200 in PN16 or PN40 (Type B1); others on request
3¨...8¨ in 150 lb RF, 3¨...4¨ in 300 lb RF; others on request
80...100A in 10K; others on request
Others on request
www.honeywell.com/ps
SMARTLINE® RM60 (FMCW)
1
2
2
2
3
34-VF-25-31 iss.4 GLO December 15 US

Advertisement

Table of Contents
loading