OPERATION
6
Menu
Function
No.
C.5.1.5
Volume Unit
C.5.1.6
Mass Unit
C.5.1.7
Custom.
Length Unit
C.5.1.8
Custom.
Length Ratio
C.5.1.9
Custom. Conv.
Unit
C.5.2
C.5.2
C.5.2
C.5.2
Passwords
Passwords
Passwords
Passwords
C5.2.2
Supervisor
C.6 Reset
C.6.2
Clear Error
Record
C.6.3
Restart
1 Units and range depend on the output function, length unit and volume unit selected. See also the table of data dependencies for the
4 mA settings in this section.
2 Units and range depend on the output function, length unit and volume unit selected. See also the table of data dependencies for the
20 mA settings in this section.
3 This function is applicable only to a device that has two outputs
Data dependencies for the 4 mA settings of outputs 1 and 2
Output function
Level
0 m
Volume
0.00 m³
Mass
0.00 kg
Distance
0 m
Ullage Volume
0.00 m³
Ullage Mass
0.00 kg
62
Function description
The volume unit displayed in operator
mode.
The mass unit displayed in operator
mode.
A non-standard length unit for the
conversion table. This is defined by the
supervisor.
The conversion factor between the
length unit selected in C.5.1.4 (Length
Unit) and C.5.1.7 (Custom. Length
Unit). This ratio is a multiple of 1 mm.
A non-standard conversion unit for the
conversion table. This is defined by the
supervisor.
To change user passwords, refer to
To change user passwords, refer to
To change user passwords, refer to
To change user passwords, refer to
these menu items.
these menu items.
these menu items.
these menu items.
This changes the supervisor password.
Push the keypad buttons up to 6 times
in any order. This will be the new
password. To confirm the change,
enter the new password a second time.
Erase the error record in menu item
B.2.6. Push [^ ^ ^ ^ ] to confirm.
If the device is not functioning properly,
this menu item will restart the device.
Push [^ ^ ^ ^ ] to confirm.
Minimum value
www.honeywell.com/ps
Selection list
m3, L, US gal, GB gal, ft3, bbl
Tons, Kg, US Tons, GB Tons
min.-max: 1...99999
Maximum value
<20 mA Setting for Level
<20 mA Setting for Volume
<20 mA Setting for Mass
<20 mA Setting for Distance
<20 mA Setting for Ullage Volume
<20 mA Setting for Ullage Mass
SMARTLINE® RM60 (FMCW)
Default
m3
Kg
LEN_FREE_
1
CO_FR_UN
[> > > > ], [^ ^ ^ ^ ], [ ],
[ ], [> > > > ], [^ ^ ^ ^ ]
Default
0 m
0 m³
0 kg
0 m
0 m³
0 kg
34-VF-25-31 iss.4 GLO December 15 US