Fitting the drive motor for the backwater flap(s)

(Option)
If the design includes a motor-driven flap control, there are one or two
drive motors included in the scope of delivery, depending on the model
type.
These are fitted as follows:
Cable marking
grey
black
Fix the drive motor <49> to the backwater flap and optionally to the redundant valve as follows.
• If the position has not already been selected, move the locking lever <50> to the CLOSED position (as
shown).
• Remove the protective cap <33>.
• Fix the drive motor <49> in place using 4 screws <32>.
In the case of pumping stations with a shallow inspection chamber depth (cone ring directly above the system
tank), the entire backwater flap assembly (quick release closures) must be removed for the drive motor to be
installed.
3.7

Installing the control unit(s)

(Position 14 in Fig. [9]) and in Fig. [10])

3.7.1 Fixing / connecting the main control unit

Install the Comfort PLUS control unit in accordance with the instructions enclosed with the unit.

3.7.2 Installing the KESSEL tele-control modem

(Option) Install the KESSEL tele-control modem in accordance with the instructions enclosed with this unit.
Installation
Function
Backwater flap
Redundant valve
60 / 264
Abb. [33]
03/2015