Installing The Optical Probe On The Backwater Flap(S) - Kessel Ecolift XL Instructions For Installation, Operation And Maintenance

Backwater lifting station
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 45
3.5

Installing the optical probe on the backwater flap(s)

Depending on the model type, there are either one or two optical probes for backwater detection included in the
scope of delivery.
These are fitted as follows:
Cable marking
none
yellow
Fitting the probe for the backwater flap
Fix the optical probe <1> to backwater flap <A and optionally B>, to
do this:
• Remove the sealing cap <46>.
• Use the sealing cap screws to fit the optical probe.
Fitting the probe for the redundant valve
Fix the optical probe <1> to backwater flap <A and optionally B>, to
do this:
• Unscrew the screws on the sealing cap <46> and remove the
sealing cap.
• Insert the adapter <47>.
• Use the sealing cap screws to fit the optical probe.
03/2015
Installation
Function
Backwater flap
Redundant valve
59 / 264
Abb. [31]
47
Abb. [32]

Advertisement