B.
Activate the dispensing valve for one minute to purge all sanitizing solution out of the syrup system
and the dispensing valve.
C.
Continue to activate the dispensing valve in cycles (" ON"for 15-seconds, " OFF" , then " ON"for
15-seconds). Repeat " ON"and " OFF"cycles for 15-cycles.
21. Repeat steps 19 and 20 preceding to purge sanitizing solution out of the remaining syrup systems and
dispensing valves.
22. Remove potable water source from the syrup system.
STEP 5. PURGE WATER OUT OF SYRUP SYSTEMS (RESTORE OPERATION)
23. Syrup Tank Systems.
A.
Noting syrup tanks CO
tor to the observed pressure setting,
B.
Connect tanks containing syrup into syrup systems.
Bag-in-Box Syrup System.
C.
Remove all bag valves from bag-in-box syrup containers outlet tubes connectors.
D.
Connect bag-in-box syrup containers into the syrup systems.
24. Place waste container under dispensing valves. Dispense from all dispensing valves to permit syrup to
purge all potable water from the syrup systems and the dispensing valves. Continue to dispense from the
dispensing valves until only syrup is dispensed from the syrup systems and valves.
WARNING: To avoid possible personal injury or property damage, do not attempt to
remove the syrup tank cover until CO
25. Dispose of waste sanitizing solution in a sanitary sewer, not in a storm drain, then thoroughly rinse the in-
side and the outside of the container that was used for sanitizing solution to remove all sanitizing solution
residue.

CLEANING DROP-IN REFRIGERATION ASSEMBLY CONDENSER COIL

(see Figure 8)
Excessive accumulation of dust, lint, and grease on the drop-in refrigeration assembly condenser coil will restrict
air flow through the coil and cause a loss of cooling. Perform the following procedure to clean the condenser
coil.
1. Unplug Unit power cord from electrical outlet.
2. Remove hood by loosening screw on top of hood, then lift hood straight up off Unit.
3. Vacuum or use a soft brush to clean condenser coil. If available, use low-pressure compressed air.
4. Clean dust and dirt from around top of refrigeration assembly.
5. Install hood on Unit and secure with screw.
6. Plug Unit power cord into electrical outlet.

CHECKING ICE WATER BATH

A " gurgle"heard from Unit indicates water level in the water tank is low and more water should be added to the
tank for maximum cooling. Before adding more water, ice water bath and ice bank should be checked for clean-
liness and water tank coils checked for excessive mineral deposit build-up.
1. Unplug Unit power cord from electrical outlet.
318832000