Dispensed Product Produces Foam As It Leaves; Dispensing Valve; Product Dispensed From All Dispensing Valves; Only Plain Water Dispensed - Cornelius VENTURE Installation Manual

Carbonated & noncarbonated post-mix dispensers
Table of Contents

Advertisement

NON-CARBONATED UNIT (CONT' D)
Trouble
DISPENSED PRODUCT
PRODUCES FOAM AS IT
LEAVES DISPENSING VALVE.
NO PRODUCT DISPENSED
FROM ALL DISPENSING
VALVES.
ONLY PLAIN WATER
DISPENSED.

ONLY SYRUP DISPENSED.

REFRIGERATION SYSTEM

Trouble
COMPRESSOR DOES NOT
OPERATE.
318832000
Probable Cause
A.
Recovery rate of refrigeration
unit exceeded, ice bank
depleted.
CAUTION: The drop-in refrigeration assembly condenser coil must be
periodically cleaned. Excessive accumulation of dust, lint, and grease
on coil will restrict cooling air flow through coil and cause
refrigeration system to overheat.
B.
Dispensing valve restricted or
dirty.
C.
Tapered gasket inside
carbonated water line swivel
nut connector distorted
restricting carbonated water
flow.
A.
Dispensing valves keyed
lock-out switch in " OFF"
position.
B.
No electrical power to Unit.
C.
Disconnected dispensing
valves power cord.
D.
Disconnected or broken wiring
to dispensing valve.
E.
Inoperative transformer or
valve solenoids.
A.
Out of syrup.
B.
Inoperable dispensing valve.
C.
Dispensing valve syrup flow
control not properly adjusted.
D.
Dispensing valve syrup flow
control or syrup lines
restricted.
A.
Water inlet supply line shutoff
valve closed.
Probable Cause
A.
Ice bank sufficient.
B.
Unit power cord unplugged,
power switch (if applicable) in
" OFF"position, or drop-in
refrigeration assembly power
cord unplugged.
50
Remedy
A.
Allow ice bank to recover.
B.
Sanitize syrup system as
instructed.
C.
Replace tapered gasket. Make
sure gasket is properly seated.
A.
Place keyed lock-out switch in
" ON"position.
B.
Plug in Unit power cord or check
for blown power fuse or tripped
circuit breaker.
C.
Connect dispensing valves power
cord.
D.
Connect or replace wiring.
E.
Replace inoperative part.
A.
Replenish syrup supply as
instructed.
B.
Repair dispensing valve.
C.
Adjust dispensing valve syrup
flow control (Water-to-Syrup
" Ratio" ) as instructed.
D.
Sanitize syrup system as
instructed.
A.
Open water inlet supply line
shutoff valve.
Remedy
A.
Refrigeration not called for.
B.
Plug in power cord(s) or place
Unit power switch (located behind
front panel) in " ON"position.