Checking Ice Water Bath; Carbonator Water Pump Yearly Maintenance Or After Water; System Disruptions; Unit Requiring Connection To A Remote Carbonator (Standard Unit) - Cornelius VENTURE Installation Manual

Carbonated & noncarbonated post-mix dispensers
Table of Contents

Advertisement

CHECKING ICE WATER BATH

A " gurgle"heard from the Unit indicates the water level in the water tank is low and more water should be added
to the tank for maximum product cooling. Water should be added to the water tank as instructed in the SER-
VICE AND MAINTENANCE section of this manual. This procedure should be performed by a qualified Service
Person.

CARBONATOR WATER PUMP YEARLY MAINTENANCE OR AFTER WATER

SYSTEM DISRUPTIONS

UNIT REQUIRING CONNECTION TO A REMOTE CARBONATOR (STANDARD UNIT)

The remote carbonator water pump water inlet strainer screen and the double liquid check valve must be in-
spected and cleaned by a qualified Service Person at least once a year under normal circumstances and after
any water system disruption (plumbing work, earthquake, etc.) Refer to manual provided with the remote carbo-
nator for the double liquid check valve inspection and cleaning procedure.

UNIT WITH BUILT-IN COLD CARBONATOR

The water pump water strainer screen and double liquid check valve must be inspected and cleaned as
instructed by a qualified Service Person at least once a year under normal circumstances and after any water
system disruption (plumbing work, earthquake, etc.). Refer to SERVICE AND MAINTENANCE section of this
manual for inspection and cleaning procedure.
CLEANING CO
GAS CHECK VALVES
2
The CO
gas check valves must be inspected and serviced as instructed at least once a year under
2
normal conditions and after any CO
system servicing or disruption. Servicing of CO
gas check valves should
2
2
be performed by qualified Service Personnel. Refer to SERVICE AND MAINTENANCE section in this manual
for inspection and servicing procedures.