Cleaning And Sanitizing; Daily Cleaning; Sanitizing; Cleaning Condenser Coil - Cornelius FCB 3 H.P. POST-MIX DISPENSER Installation & Service Manual

Two-flavor w/hot-gas defrost and v3+ features
Table of Contents

Advertisement

Make sure CO
cylinder shutoff valve is fully opened and regulator assembly 1800-psi gage indicator is not in
2
shaded (''change CO
cylinder'') portion of dial. If so, CO
2
instructed.

CLEANING AND SANITIZING

DAILY CLEANING

Daily; or more often if necessary, wash all external surfaces of Unit, rinse with clean water, then wipe dry with
clean soft cloth. DO NOT USE ABRASIVE CLEANERS. Remove and wash drip tray and cup rest with warm
water and mild detergent, rinse with clean water, then install them on Unit.

SANITIZING

The Unit should be sanitized as instructed every 120-days and before and after storage periods following parent
company requirements and sanitizer manufacturers recommendations.

CLEANING CONDENSER COIL

Circulating air, required to cool the refrigeration system condenser coil (see Figure 15), is drawn in through
louvers on front and exhausted out through louvers on sides and back of Unit. Restricting air circulation through
the Unit will decrease its cooling efficiency. The condenser coil air filter and the condenser coil must be cleaned
periodically as instructed in SERVICE AND MAINTENANCE section.

LUBRICATION

The carbonator pump motor must be lubricated as instructed.

ADJUSTMENTS

CARBONATED WATER FLOW RATE

The black carbonated water flow regulators (see applicable Figure 2 and 5), which control carbonated water
flow rate into product blender tanks, are factory adjusted and normally do not require further adjustment. If
adjustment should become necessary, adjust as instructed in SERVICE AND MAINTENANCE section.
CO
REGULATORS
2
Primary CO
Regulator.
2
The primary CO
regulator (see Figure 2) regulates CO
2
syrup system if used) and also to the secondary CO
the primary CO
regulator, adjust as instructed in SERVICE AND MAINTENANCE section.
2
Secondary CO
Regulators.
2
The secondary CO
regulators (see applicable Figure 2 and 5) regulate CO
2
tanks and the product blender tanks. If necessary to adjust secondary CO
SERVICE AND MAINTENANCE section.
cylinder is almost empty and must be replaced as
2
pressure to the soft drink tanks (also to the bag-in-box
2
regulators located inside the Unit. If necessary to adjust
2
2
regulators, adjust as instructed in
2
23
pressure to the carbonated water