Service And Maintenance; Preparing Unit For Shipping, Storing, Or Relocating; Hood And Front Panel Removal; Hood Removal - Cornelius VENTURE Installation Manual

Carbonated & noncarbonated post-mix dispensers
Table of Contents

Advertisement

This section describes service and maintenance procedures to be performed on the Unit.
IMPORTANT: Only qualified personnel should service internal components or electrical wiring.
WARNING: Disconnect electrical power to the Unit to prevent personal injury before
attempting any internal maintenance. Only qualified personnel should service the internal
components or electrical wiring.

PREPARING UNIT FOR SHIPPING, STORING, OR RELOCATING

CAUTION: Before shipping, storing, or relocating this Unit, the syrup systems must be
sanitized and all sanitizing solution must be purged from the syrup systems. All water must
also be purged from the plain and carbonated water systems. A freezing ambient
environment will cause residual water in the Unit to freeze resulting in damage to internal
components.

HOOD AND FRONT PANEL REMOVAL

(see Figure 8)

HOOD REMOVAL

CAUTION: Do not place or store anything on top of the Unit.
Loosen screw on top of hood, then lift hood straight up and off the Unit.

FRONT ACCESS PANEL REMOVAL

Remove two screws (if applicable) securing front access panel to Unit, then remove panel..

PERIODIC INSPECTION

1. Clean the drop-in refrigeration assembly condenser coil every 30-days as instructed in this manual section.
Cleaning the condenser coil should be performed by a qualified Service Person. DO NOT place objects on
top of or on back side of the Unit hood. Restricting circulating air in or out of the Unit hood will cause the
refrigeration system to overheat.
2. Check dispensing valves for dripping that indicates leaking and repair as necessary.
3. Periodically, pull up on carbonated water tank relief valve momentarily on units with built in carbonators.

ADJUSTMENTS

CO
REGULATORS ADJUSTMENTS
2
WARNING: CO
CO
(carbon dioxide) gas leaks in the entire CO
2
suspected, particularly in a small area, immediately ventilate the contaminated area before
attempting to repair the leak. Personnel exposed to high concentration of CO
tremors which are followed rapidly by loss of consciousness and suffocation.

SERVICE AND MAINTENANCE

displaces oxygen. Strict attention must be observed in the prevention of
2
and soft drink system. If a CO
2
25
gas leak is
2
gas will experience
2
318832000