Preventative Maintenance; Overview; Maintenance Schedule; Annual Maintenance - Cornelius Nitropro Mini Service And Preventative Maintenance Manual

Specialty beverage dispenser
Table of Contents

Advertisement

4.0 PREVENTATIVE MAINTENANCE

4.1 O
VERVIEW
Perform the procedures in this section at the intervals indi‐
cated to ensure consistent, safe and clean operation of the
unit. These are provided in addition to the routine cleaning
and sanitizing procedures included in the Installation &
Operation manual.
4.2 M
S
AINTENANCE
CHEDULE
Table 4‐1 ‐ Maintenance Schedule
Procedure
Refrig. condenser & cabinet fan cleaning

Ice bank level check

Concentrate pump mix ratio verification
Components visual inspection
Concentrate‐pump hose replacement
4.3 A
M
NNUAL
AINTENANCE
4.3.1 Refrigeration Condenser & Cabinet Fan Cleaning
To ensure optimal cooling efficiency, clean the fan blades
and grilles of any collected dust and debris. (The use of com‐
pressed or canned air to clean the refrigeration condenser
fan blades is adequate.)
Figure 4‐1 ‐ Fans
© 2019, Cornelius Inc. All Rights Reserved
4.3.2 Ice Bank Level Check
The water level in the ice bank may require periodic topping
off to ensure optimal operation. Check and refill it as indi‐
cated below.
The fill tube is located behind the front splash panel and is
capped with a red plug.
The small, black, overflow tube, connected to an internal
standpipe, will emit water during manual refill when the
water level reaches the full mark.
Interval
Section
(Months)
4.3.1
12
4.3.2
12
4.3.3
12
4.3.4
12
4.3.5
12
NOTE: When the fill tube is in its stored position (as shown
in Fig. 4‐2) it also serves as a 'sight glass' indicating the bank
water level.
1) Remove the drip tray and splash panel to reveal the front
of the ice bank.
2) Observe the fill tube and the water level in it. If the water
level is below the top of the tube arc, add water to the ice
bank.
3) Add filtered store water through the fill tube after
extending it from its storage position and removing the red
cap. Add water until a trickle runs out of the black overflow
tube.
4) Cap the fill tube and return it to its storage position.
‐ 15 ‐
Nitropro Mini Service Manual
Figure 4‐2 ‐ Ice Bank Fill & Overflow Tubes
Publication Number: 548000106SER