REFRIGERATION SYSTEM (CONT' D)
Trouble
AGITATOR MOTOR NOT
OPERATING. (cont' d)
318832000
Probable Cause
C.
No power source (blown fuse
or tripped circuit breaker).
D.
Agitator motor propeller
obstructed.
E.
Low voltage.
F.
Loose, disconnected, or
broken wiring.
G.
Inoperative agitator motor.
52
Remedy
C.
Replace fuse or reset circuit
breaker. (NOTE: Fuse or circuit
breaker are not part of Unit).
D.
Remove obstruction.
E.
Voltage must be at least 103 volts
(115 VAC unit) or 208 (230 VAC
unit) at compressor terminals
when compressor is trying to
start.
F.
Tighten connections or replace
broken wiring.
G.
Replace agitator motor.