Installation; Connecting Drip Tray Drain Hose; Connecting Plain Water Source Line(S) To Unit - Cornelius VENTURE Installation Manual

Carbonated & noncarbonated post-mix dispensers
Table of Contents

Advertisement

4. 60 HZ Units
Place Unit power switch (if applicable) in " OFF"Position. ON UNIT WITH BUILT-IN COLD CARBONATOR,
MAKE SURE CARBONATOR WATER PUMP MOTOR SWITCH, LOCATED ON REFRIGERATION AS-
SEMBLY CONTROL BOX, IS IN " OFF"POSITION.
50 HZ Units
On Units with built-in cold carbonator (see Figure 8) make sure carbonator water pump motor switch,
located on refrigeration assembly control box, is in " OFF"position.
WARNING: The Unit must be electrically grounded to avoid possible fatal electrical shock
or serious injury to the operator. The Unit power cord is equipped with a three-prong plug.
If a three-hole (grounded) electrical outlet is not available, use an approved method to
ground the Unit.
5. 60 HZ Units
A.
Plug Unit power cord into an accessible properly grounded electrical outlet with GFCI (ground fault
circuit interrupt).
B.
Place Unit power switch (if applicable) in " ON"position. Compressor, condenser fan motor, and agita-
tor motor will start and begin forming an ice bank. When full ice bank has been formed, compressor
and condenser fan motor will stop but agitator motor will continue to operate circulating ice water bath
in water tank. ON UNIT WITH BUILT-IN COLD CARBONATOR (see Figure 8), DO NOT PLACE CAR-
BONATOR WATER PUMP MOTOR SWITCH IN " ON"POSITION AT THIS TIME.
50 HZ Units
C.
Plug Unit power cord into an accessible properly grounded electrical outlet with ELCB (earth leakage
circuit breaker).
D.
Compressor, condenser fan motor, and agitator motor will start and begin forming an ice bank. When
full ice bank has been formed, compressor and condenser fan motor will stop but agitator motor will
continue to operate circulating ice water bath in water tank. ON UNIT WITH BUILT-IN COLD CARBO-
NATOR (see Figure 8), DO NOT PLACE CARBONATOR WATER PUMP MOTOR SWITCH IN " ON"
POSITION AT THIS TIME.

INSTALLATION

CONNECTING DRIP TRAY DRAIN HOSE

NOTE: Connection of the drip tray drain hose to a permanent drain is recommended. Drip tray drain
hose routed to waste container is not recommended due to sanitation and cleaning problems.
1. Route lower end of drip tray drain hose to and connect to a permanent drain.
2. Install DRIP TRAY in position on the Unit, then place CUP REST in drip tray.

CONNECTING PLAIN WATER SOURCE LINE(S) TO UNIT

NOTE: IMI Cornelius Inc. recommends that a water shutoff valve and water filter be installed in plain
water inlet supply line. A Cornelius Water Filter (P/N 313860000) and Quick Disconnect Set
(P/N 313867000) are recommended. The plain water source to the equipment shall be installed with ade-
quate backflow protection to comply with applicable Fereral, State, and local codes.
318832000