Check And Top-Off Water Ice Bath; Annually; Replace Pump Tubing And Clean Cabinet; Removing Pump Platform(S) - Cornelius QUEST ELITE 2 FLAVOR Installation Manual

Table of Contents

Advertisement

QUEST ELITE 4 Flavor Installation, Service & Decommissioning Manual

Check and Top-Off Water Ice Bath

1. Remove the drip tray and lower splash panel.
Lower Splash Panel
If the Ice bath level is below the FULL indicator, top it off with water. Refer page 9 for the ice bath procedure
A
NNUALLY

Replace Pump Tubing and Clean Cabinet

A replacement pump tubing kit, part # 45098, is available. The kit consists of one pre-cut length of pump tubing, two white plastic
hose clamps, and instructions.

Removing Pump Platform(s)

1. Remove the concentrate containers from the dispenser and place them in a refrigerator.
2. Remove the cabinet shelf that the concentrate containers sit on.
3. Flush the system prior to removing the pump platform (refer to the Daily). Remove the dispense nozzles and static
mixers.
4. Unplug the water line quick disconnect by pressing the gray button (See Figure 22).
Bottle Adapter
Concentrate
Juice Inlet
Delivery Tubes
Locking Latch
5. Slide the locking latch forward. Lift the platform slightly and pull forward to gain access to the electrical connector (see
Figure 22).
Publication Number:721Q14101MNL
Cup Rest
Figure 21. Drip Tray and Cup Rest
Water Inlet
Quick Connector
BRIX Adjustment Screw
Figure 22. Interior Details
Water Manifold
Pump Body Screws
Water Solenoid
- 18 -
© 2022, Marmon Foodservice Technologies Inc.
Drip Tray
Pump Motor
Front & Rear
Pump Halves