Duct Adapter Kit

The 10" Ported Duct Adapter Kit allows the connection of 10" ducting to either or both
ends of the Revolution unit to enable pulling air from a remote location, exhausting
filtered air to a remote location, or even installing the Revolution itself outside of the
location the air is being filtered in.
The Duct Adapter Kit comes with the following parts:
Duct Adapter
Bracket (2)
Port Duct
Gasket (2)
The Upper Duct Adapter can be installed by itself. When the Lower Duct Adapter is
installed, either the Wall or Ceiling Mounting Kit must be used in order to keep the
bottom of the unit off of the ground to allow for air intake.
Install Upper Duct Adapter
To connect the upper Duct Adapter, first peel the backing off one of the Duct Gaskets
and place it over the mounting holes on the top of the unit, lining up the screw cutouts.
Then set one of the Duct Adapter Brackets onto the top of the Revolution unit and
secure it using eight of the included bracket screws.