Hydronix Hydro-Control VI Operator's Manual page 60

Hide thumbs Also See for Hydro-Control VI:
Table of Contents

Advertisement

Alarm Configuration
Max Dry Mix Time Exceeded Alarm
Max Wet Mix Time Exceeded Alarm
These alarms are triggered when the Auto-track is running and the sensor reading has not
stabilised within the configured Auto-track values before the end of the Dry Mix and Wet Mix Times
set in the recipe.
Check:
The Auto-track control settings are set correctly. The frequency this alarm is triggered can
be reduced by decreasing the Auto-track Mix Time or increasing the allowed Mix Deviation,
either in the recipe or the system parameters.
The recipe mix time parameters are set to be long enough for the mix to stabilise.
Sensor Fault Alarm
This alarm is triggered when the Hydro-Control detects a problem with the RS485 communications
with the sensor.
Check:
Ensure that communications cables are routed away from heavy duty power cables and
electrical equipment.
Ensure cables are of the required standard
Ensure that the cable screen is connected at the sensor end only.
Further information on cabling can be found in the sensor user guides.
60
Hydro-Control VI Operators Guide HD0456 Rev 1.7.1
Chapter 9

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Hydro-Control VI and is the answer not in the manual?

Table of Contents