Chapter 6
Mix Control
1.4
Recipe parameter
Pre-wet Water Control
Method
Pre-wet Moisture Target
Control Method
Moisture Target
Plus/Minus Tolerance
Unscaled Mode
Figure 12: The recipe editor screen (page 2)
Description
This is the method used to control the addition of the pre-wet water.
If Preset is used, then the fixed quantity of water specified on Page
1 is used. If the method is set to Auto then the addition is governed
by the pre-wet moisture target.
This parameter defines the way in which the pre-wet water addition
is controlled. It has three settings, Preset, Auto and Calc. These
methods are discussed in Chapter 5.
This parameter defines the way in which the main water addition is
controlled. It has three settings, Preset, Auto and Calc. These
methods are discussed in Chapter 5.
If the main Control Method is set to Auto or Calc then this setting
defines the moisture target (as a moisture percentage) that the
automatic mode is using.
These settings define the limits (as a moisture percentage) used
for the upper and lower limits before alarms are triggered to indicate
the final moisture is out of tolerance with the moisture target defined
in the previous parameter.
This indicates the sensor measurement mode used for the recipe.
Hydro-Control VI Operators Guide HD0456 Rev 1.7.1
Editing Recipes
29