Chapter 6
This chapter explains how to edit a recipe and describes the recipe parameters and how they are used.
Once a recipe has been created, it will appear in the list on the recipe overview screen. To edit any
recipe simply press on it to select it in the list, and then press the Edit Recipe button.
1 The Recipe Editor
[Menu->Recipe Overview->Edit Recipe]
Recipe Details
1.1
Recipe parameter
Recipe Number
Batch Number
Recipe Name
Water Addition
1.2
Recipe parameter
2 Step Addition
Pre-wet Water
Figure 11: The recipe editor screen (page 1)
Description
This is the number of the recipe in the Hydro-Control VI.
This is the number of the last batch made.
This is the name of the recipe which is displayed on the Overview
Screen.
Description
This enables the two step addition mode, which splits the main
water addition into two stages.
Admixture signal is activated. This can be used whilst dosing
admixtures that have a large effect on the sensor calibration to
keep the moisture display accurate.
This is the fixed amount of water to add during the pre-wet phase
of the mix cycle if the Pre-wet Water Control Method is set to Preset
Mode. If not using Pre-wet Water then set this value to zero.
During the second stage the
Hydro-Control VI Operators Guide HD0456 Rev 1.7.1
Editing Recipes
27
Need help?