Editing Recipes
Local Auto-track Settings
1.5
Recipe parameter
Initial Mix Enable
Pre-wet Mix Enable
Dry Mix Enable
Wet Mix Enable
Local Auto-track Control
Initial Mix Time
Initial Mix Deviation
Pre-wet Mix Time
Pre-wet Mix Deviation
Dry Mix Time
Dry Mix Deviation
30
Hydro-Control VI Operators Guide HD0456 Rev 1.7.1
Description
This setting enables the Auto-track feature for the initial mix phase
of the recipe.
For more information on this feature see Chapter 8.
This setting enables the Auto-track feature for the pre-wet mix
phase of the recipe.
For more information on this feature see Chapter 8.
This setting enables the Auto-track feature for the dry mix phase of
the recipe.
For more information on this feature see Chapter 8.
This setting enables the Auto-track feature for the wet mix phase of
the recipe.
For more information on this feature see Chapter 8.
If enabled the recipe will use the locally set parameters for the Auto-
track function instead of the ones set on the system parameters
page.
When using Auto-track control, this is the amount of time that the
Dry Mix must be within the Initial Mix Deviation below to continue.
If the sensor signal has not stabilised within this window by the end
of the Initial Mix Time the system will prompt the operator to
continue regardless of whether it has stabilised or not.
This is the maximum deviation that the sensor signal must be within
in order for the system to continue.
When using Auto-track control, this is the amount of time that the
pre-wet Mix must be within the pre-wet Mix Deviation below to
continue. If the sensor signal has not stabilised within this window
by the end of the pre-wet Mix Time, the system will prompt the
operator to continue regardless of whether it has stabilised or not.
This is the maximum deviation that the sensor signal must be within
in order for the system to continue.
When using Auto-track control, this is the amount of time that the
Dry Mix must be within the Dry Mix Deviation below to continue. If
the sensor signal has not stabilised within this window by the end
of the Dry Mix Time the system will prompt the operator to continue
regardless of whether it has stabilised or not.
This is the maximum deviation that the sensor signal must be within
in order for the system to continue.