Hydronix Hydro-Control VI Operator's Manual page 48

Hide thumbs Also See for Hydro-Control VI:
Table of Contents

Advertisement

Using Moisture Control
Loading
100
Unscaled
0
Dry weights
2.11
If the raw material dry weights change between batches then this value must be updated in the
recipe. This can either be manually entered for each batch or sent by the control system to the
Hydro-Control. Using incorrect values will result in the calculation incorrectly determining the
moisture change for the calibration.
Even when using a mixer moisture control system, it is important to correct for the weight of the
moisture in the raw material being used to ensure that the mix design is consistent. Any
moisture in the raw materials will affect the weight of raw material dosed and will affect the
aggregate/cement ratio.
It is important to use a control system that controls all of the raw materials being added into the
mixer, in particular all materials should be added to the mixer in the same order each time and
admixtures should be dosed at the same time during the cycle so that the effect of any materials
on the sensor signal is consistent.
48
Hydro-Control VI Operators Guide HD0456 Rev 1.7.1
Mixer
Dry Mix Time
Largest Unscaled
difference
Figure 22: Comparing Measurement Modes
Main Water
Wet Mix
Addition
Time
Very small Unscaled
difference
Chapter 8
Discharge
Time