Chapter 6
Temperature Correction Settings
1.9
Recipe parameter
Temperature Set Point
Temperature Coefficient
Description
This is the base temperature for the temperature coefficient to work
from.
This is the change in moisture per degree Celsius that the current
temperature is different from the Temperature Set Point that is
added to or subtracted from the target unscaled. This is used to
allow the concrete to vary depending on the temperature to allow
for the increased rate of hydration in hotter atmospheres.