Electrical Connections; Power Connections - gefran GFX4-IR Series Installation And Operation Manual

4-zone modular power controller for ir lamps and inductive loads
Table of Contents

Advertisement

3.1
p
ower connections
Figure 12
model without fuse holder
F1,F2,F3,F4/N
Line connection terminals
U1,U2,U3,U4
Load connection terminals
Table 4
Model
max current
0,2 - 6mm
rigid
0,2 - 4mm
flexible
0,25 - 4mm
0,25 - 4mm
* UL certification
14
3 • ELECTRICAL CONNECTIONS
30kW
16A
24-10AWG
0,2 - 6mm
2
24-10AWG
0,2 - 4mm
2
23-10AWG
0,25 - 4mm
2
23-10AWG
0,25 - 4mm
2
0,5 - 0,6Nm
Figure 13
model with fuse holder
F1,F2,F3,F4/N
Line connection terminals
U1,U2,U3,U4
Load connection terminals
60kW
32A (30A)*
24-10AWG
0,5 - 16mm
2
24-10AWG
0,5 - 10mm
2
23-10AWG
0,5 - 10mm
2
23-10AWG
0,5 - 10mm
2
0,5 - 0,6Nm
80404L_MHW_GFX4-IR_03-2020_ENG
80kW
57A (40A)*
20-6AWG
2
20-7AWG
2
20-7AWG
2
20-7AWG
2
1,2 - 1,5Nm

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gfx4-ir 30Gfx4-ir 60Gfx4-ir 80Gfx4-ir 30-d-2-f