Configuring SNMP
Creating an SNMPv3 group
Use the snmp-server group command to create an SNMPv3 group. Use the no form of
●
the command to remove the specified group. You can define the following parameters with
this command:
- The name of the group
- The SNMP security model
- The security level, for a group with the SNMPv3 security model
- The name of a read view to which the group maps users
- The name of a write view to which the group maps users
- The name of a notify view to which the group maps users
Views
There are three types of views:
Read Views. Allow read-only access to a specified list of Object IDs (OIDs) in the MIB tree
●
Write Views. Allow read-write access to a specified list of OIDs in the MIB tree
●
Notify Views. Allow SNMP notifications from a specified list of OIDs to be sent
●
Each view consists of a list of OIDs in the MIB tree. This list can be created using multiple
snmp-server view commands to either add OIDs to the list or exclude OIDs from a list of all
of the OIDs in the G450's MIB tree. You can use wildcards to include or exclude an entire
branch of OIDs in the MIB tree, using an asterisk instead of the specific node. For a list of MIBs
and their OIDs, see
Creating an SNMPv3 view
To create an SNMPv3 view, the following information must be provided:
ViewName. A string of up to 32 characters representing the name of the view
●
ViewType. Indicates whether the specified OID is included or excluded from the view
●
OIDs. A list of the OIDs accessible using the view
●
332 Administration for the Avaya G450 Media Gateway
G450 MIB files
on page 649.