Maintenance; Maintenance Work; Cleaning; Malfunctions - Festo MS6-SV E-10V24 Series Instructions Manual

Soft start/quick exhaust valve
Hide thumbs Also See for MS6-SV E-10V24 Series:
Table of Contents

Advertisement

Maintenance

10
Maintenance
10.1

Maintenance work

NOTICE!
Failure of the safety function
Clogging of the cushioning body of an unsuitable silencer may result in reduced bleeding (back pres-
sure). This may result in failure of the safety function.
Use the silencer UOS-... intended for the device exclusively.
Check the silencer regularly and replace if necessary.
10.2

Cleaning

1. Switch off energy sources:
Operating voltage
Compressed air
2. Clean the outside of the product as required. Approved cleaning agents are soap solutions (max.
+50 °C), petroleum ether and all non-abrasive cleaning agents.
11

Malfunctions

11.1

Diagnostics

LED display
Operating statuses and errors are indicated by flashing light-emitting diodes.
Power LED (green)
Off
lights for approx. 6 s after
switch on
flashes once a second
continuously on
4x briefly
Tab. 7 LED display
Display of error codes
The error code is displayed by 4 short flash pulses of the Power LED (green). Then the Error LED (red)
displays the error code (number of flash pulses = error code). The flash pulses for both LEDs repeat
continuously. The LEDs only stop flashing when the operating voltage is switched off in order to clear
the error.
Overview of error codes:
24
Error LED (red)
Off
lights for approx. 6 s after
switch on
Off
Off
flashes once a second
Meaning
Operating voltage not applied
Product runs through all tests
during start-up
Product is in exhausted status
Product is in pressurised status
Product is waiting for the signal
(S34) with monitored start
error code
Festo — MS6-SV-...-E-10V24 — 2019-10d

Hide quick links:

Advertisement

Table of Contents
loading