Lenovo System x3850 X6 Installation And Service Manual page 301

Hide thumbs Also See for System x3850 X6:
Table of Contents

Advertisement

c.
Gently twist the handle on the installation tool clockwise to the closed position and lift the
microprocessor out of the socket.
Step 10. Place the microprocessor on a static-protective surface. Remove the microprocessor from the
installation tool by twisting the handle counterclockwise.
Handle
Installation
tool
Step 11. If you are instructed to return the microprocessor, follow all packaging instructions, and use any
packaging materials for shipping that are supplied to you. Do not return the microprocessor
installation tool.
Replacing a microprocessor and heat sink
This information provides instructions on how to replace a microprocessor and heat sink.
To replace a microprocessor and heat sink, complete the following steps:
Attention: When you handle static-sensitive devices, take precautions to avoid damage from static
electricity. For details about handling these devices, see "Handling static-sensitive devices" on page 46.
Notes:
• Use the microprocessor installation tool that came with the new microprocessor kit to remove the
microprocessor from the server.
• Be extremely careful when handling the microprocessor, the microprocessor socket contacts are very
fragile.
• Do not allow the thermal grease on the microprocessor and heat sink to come in contact with anything.
Contact with any surface can compromise the thermal grease and the microprocessor socket.
• Do not touch the microprocessor contacts. Contaminants on the microprocessor contacts, such as oil
from your skin, can cause connection failures between the contacts and the socket.
• Be sure to only install microprocessors that have the same speed, number of cores, and frequency.
• Each microprocessor socket must always contain either a socket cover or a microprocessor and heat
sink.
• Be sure to use only the microprocessor installation tool provided with the new microprocessor to remove
or install the microprocessor. Do not use other tools.
• The microprocessor installation tool has the microprocessor installed on the tool, and might have a
protective cover over the microprocessor. Do not use the tool or remove the cover from the
microprocessor until you are instructed to do so.
• The server supports up to four (per 4U server) Intel Xeon dual-core or quad-core microprocessors (one
microprocessor on each compute book). See
microprocessors.
1. Install the microprocessor:
a. Make sure that the microprocessor socket levers and retainer are in the open position.
Microprocessor
http://www.lenovo.com/serverproven/
for a list of supported
.
Chapter 6
Removing and replacing components
287

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3950 x66241

Table of Contents