Power Supply has detected a critical PS Therm fault or PS Invalid CFG fault.
May also be shown as 800702081381ffff or 0x800702081381ffff
Severity
Error
Serviceable
yes
Automatically notify support
no
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0522
User Response
For a PS Therm fault
1. Check for Power Supply with PS fault in the IMM event log
2. Replace the Power Supply that has the PS Fault
PS Invalid CFG
Telco sytems require all 4 power supplies to be populated and DC only.
Related links
– Solving power problems
– Installing power supplies
– Removing a 1400-watt or 900-watt hot-swap power supply
– Removing a 750-watt -48 volt to -60 volt dc power supply
– Replacing a 1400-watt or 900-watt hot-swap power supply
– Replacing a 750-watt -48 volt to -60 volt dc power supply
• 8007020c-2581ffff : Sensor [SensorElementName] has transitioned to critical from a less severe
state.
IMM has reported a SMI Lane Failed.
May also be shown as 8007020c2581ffff or 0x8007020c2581ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0522
Appendix C. Integrated management module II (IMM2) error messages