Lenovo System x3850 X6 Installation And Service Manual page 708

Hide thumbs Also See for System x3850 X6:
Table of Contents

Advertisement

1. Reboot the system.
2. If error persists, or boot is unsuccessful, (Trained service technician only) Replace the system
board.
Related links
– Removing the standard I/O book
• 806f002b-2101ffff : A hardware change occurred on system [ComputerSystemElementName].
The Scale Config sensor reports a Hardware Changed occurred.
May also be shown as 806f002b2101ffff or 0x806f002b2101ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0436
User Response
Information only; no action is required.
• 806f0107-0301ffff : An Over-Temperature Condition has been detected on
[ProcessorElementName].
The microprocessor 1 temperature has risen above the critical level, causing a hard shutdown of the node.
May also be shown as 806f01070301ffff or 0x806f01070301ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0036
User Response
Complete the following steps:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are
in place and correctly installed.
694
System x3850 X6 and x3950 X6 Installation and Service Guide