Lenovo System x3850 X6 Installation And Service Manual page 901

Hide thumbs Also See for System x3850 X6:
Table of Contents

Advertisement

Prefix: PLAT ID: 0168
User Response
At the next maintenance opportunity:
1. Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed.
2. If the node has recently been installed, moved, serviced, or upgraded, verify that the eXFlash
DIMM is properly seated and visually verify that there is no foreign material in any DIMM
connector on that memory channel. If either of these conditions is found, correct and retry with
the same eXFlash DIMM. (Note: Event Log may contain a recent 00580A4 event denoting
detected change in DIMM population that could be related to this problem.)
3. Check IBM support site for an applicable service bulletin or firmware update that applies to this
eXFlash error.
4. If problem persists and there are no other eXFLash DIMMs with the same indication, confirm that
the eXFlash DIMM is under warranty before replacement.
Related links
– Server features and specifications
– Removing a compute book
– Replacing a compute book
– Removing the compute book cover
– Replacing the compute book cover
– Removing a memory module
– Replacing a memory module
– eXFlash DIMMs
• 806f020d-2b820812 : Failure Predicted on [NumericSensorElementName] for array
[ComputerSystemElementName].
The eXFlash Proxy Service reported a failure predicted (PFA) on the eXFlash DIMM 18 in Compute Book 2.
May also be shown as 806f020d2b820812 or 0x806f020d2b820812
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
At the next maintenance opportunity:
1. Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed.
2. If the node has recently been installed, moved, serviced, or upgraded, verify that the eXFlash
DIMM is properly seated and visually verify that there is no foreign material in any DIMM
connector on that memory channel. If either of these conditions is found, correct and retry with
the same eXFlash DIMM. (Note: Event Log may contain a recent 00580A4 event denoting
detected change in DIMM population that could be related to this problem.)