Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Redundant Power Supply
SNMP Trap ID
9
CIM Information
Prefix: PLAT ID: 0802
User Response
1. Power Unit: Check if Power Supply is missing, unplugged.
2. Check the power supply LEDs, see "Power-supply LEDs"
3. Replace the affected power supply.
Related links
– Solving power problems
– Installing power supplies
– Removing a 1400-watt or 900-watt hot-swap power supply
– Removing a 750-watt -48 volt to -60 volt dc power supply
– Replacing a 1400-watt or 900-watt hot-swap power supply
– Replacing a 750-watt -48 volt to -60 volt dc power supply
• 800b010a-1e81ffff : Redundancy Lost for [RedundancySetElementName] has asserted.
Fan Redundancy in Zone 1 has been lost.
May also be shown as 800b010a1e81ffff or 0x800b010a1e81ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0802
User Response
1. Reseat the failing fan indicated by the lit LED on the fan.
2. Replace Fan.
Related links
– Removing a hot-swap fan assembly
• 800b010a-1e82ffff : Redundancy Lost for [RedundancySetElementName] has asserted.
Fan Redundancy in Zone 2 has been lost.
May also be shown as 800b010a1e82ffff or 0x800b010a1e82ffff