Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
Replace the hard disk drive at the next maintenance period.
Related links
– Removing 2.5-inch and 1.8-inch hot-swap drives
– Replacing 2.5-inch and 1.8-inch hot-swap drives
• 806f020d-040fffff : Failure Predicted on [NumericSensorElementName] for array
[ComputerSystemElementName].
Failure predicted (PFA) on the hard drive 15.
May also be shown as 806f020d040fffff or 0x806f020d040fffff
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
Replace the hard disk drive at the next maintenance period.
Related links
– Removing 2.5-inch and 1.8-inch hot-swap drives
– Replacing 2.5-inch and 1.8-inch hot-swap drives
• 806f020d-2b810801 : Failure Predicted on [NumericSensorElementName] for array
[ComputerSystemElementName].
The eXFlash Proxy Service reported a failure predicted (PFA) on the eXFlash DIMM 1 in Compute Book 1.
May also be shown as 806f020d2b810801 or 0x806f020d2b810801
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes