Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0806
User Response
This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of
the Info Center for the appropriate user response.
Related links
– Finding the UEFI (POST) error code
• 800b0508-1381ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName] has
asserted.
Power unit is no longer in the redundant state and no longer capable of providing the power needs to
operate the system.
May also be shown as 800b05081381ffff or 0x800b05081381ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Redundant Power Supply
SNMP Trap ID
9
CIM Information
Prefix: PLAT ID: 0810
User Response
1. Check if Power Supply is missing, unplugged.
2. Check the power supply LEDs, see "Power-supply LEDs"
3. Replace the affected power supply.
Related links
– Solving power problems
– Removing a 1400-watt or 900-watt hot-swap power supply
– Removing a 750-watt -48 volt to -60 volt dc power supply
– Replacing a 1400-watt or 900-watt hot-swap power supply
– Replacing a 750-watt -48 volt to -60 volt dc power supply