Table 20: Standards And Rated Conditions For Rail Applications (En 50155) - WAGO 750-606/040-000 Manual

Power supply 24 vdc xtr supply module; 24 vdc; extreme, for intrinsically safe xtr modules for wago i/o system 750 xtr
Table of Contents

Advertisement

34
Device Description
Table 19: EMC – Emission of Interference
Standard
Conducted Emission of Interference – Line Connection DC Voltage
• EN 61000-6-3
• EN 60255-26
• EN 55032 Class A
*)
QP = Quasi Peak Detector; AV = Average Detector
**)
If necessary, please find different data in the section "Approval" (regarding approval for
EMC A or EMC B).

Table 20: Standards and Rated Conditions for Rail Applications (EN 50155)

4.1 Rated Operating Conditions
4.1.1 Altitude above sea level
4.1.2 Ambient operating temperature
4.1.3 Shock and vibration
4.1.4 Relative humidity
5.1 Power Supply
5.1.1.1 Master voltage fluctuations
5.1.1.2 Power interruptions
5.4 Surge, ESD, Burst Tests
5.5 EMC (Emission of Interference,
Immunity to Interference)
9.11 Materials (Fire Protection)
WAGO is a company certified in accordance with the IRIS quality standard.
Manual
Version 2.0.0
750-606/040-000 Power Supply 24 VDC XTR for Ex i XTR Modules
Minimum voltage
Maximum voltage
WAGO I/O SYSTEM 750 XTR
*)
Test Value
79 dB(µV) QP, 0.15 MHz ... 0.5 MHz
66 dB(µV) AV, 0.15 MHz ... 0.5 MHz
73 dB(µV) QP, 0.5 MHz ... 30 MHz
60 dB(µV) AV, 0.5 MHz ... 30 MHz
Class / Standard Compliance
AX (EN 50125-1)
TX
1A and 1B (EN 61373)
95 % (coated PCBs)
0.725 × U
1.3 × U
n
S1
EN 50121-3-2
EN 50121-3-2
EN 50121-4
EN 50121-5
EN 45545-2
Hazard level HL3
n

Advertisement

Table of Contents
loading