750-606/040-000 Power Supply 24 VDC XTR for Ex i XTR Modules
Table 19: EMC – Emission of Interference
Standard
Enclosure Emission of Interference
• EN 61000-6-3
• EN 55032 Class B
• EN 61000-6-4
• EN 60255-26
• EN 55011 Class A
• EN 55032 Class A
• Shipbuilding
• Shipbuilding
Conducted Emission of Interference – Line Connection AC Voltage
• EN 61000-6-3
• EN 55032 Class B
• EN 61000-6-4
• EN 55011 Class A
• EN 50121-3-2
Conducted Emission of Interference – Line Connection
• Shipbuilding
• Shipbuilding
Test Value
30 dB(µV/m), QP, 30 MHz ... 230 MHz
37 dB(µV/m), QP, 230 MHz ... 1 GHz
70 dB(µV/m), Peak, 1 GHz ... 3 GHz
50 dB(µV/m), AV, 1 GHz ... 3 GHz
74 dB(µV/m), Peak, 3 GHz ... 6 GHz
54 dB(µV/m), AV, 3 GHz ... 6 GHz
40 dB(µV/m), QP, 30 MHz ... 230 MHz
47 dB(µV/m), QP, 230 MHz ... 1 GHz
76 dB(µV/m), Peak, 1 GHz ... 3 GHz
56 dB(µV/m), AV, 1 GHz ... 3 GHz
80 dB(µV/m), Peak, 3 GHz ... 6 GHz
60 dB(µV/m), AV, 3 GHz ... 6 GHz
**)
80 dB(µV/m) ...50 dB(µV/m), QP,
(Class B)
150 kHz ... 300 kHz
50 dB(µV/m) ... 34 dB(µV/m), QP,
0.3 MHz ... 30 MHz
54 dB(µV/m), QP, 30 MHz ... 2 GHz
24 dB(µV/m), QP, 156 MHz ... 165 MHz
**)
80 dB(µV/m) ... 50 dB(µV/m), QP,
(Class A)
150 kHz ... 30 MHz
60 dB(µV/m) ... 54 dB(µV/m), QP,
30 MHz ... 100 MHz
54 dB(µV/m), QP, 100 MHz ... 2 GHz
24 dB(µV/m), QP, 156 MHz ... 165 MHz
Standard not applicable
Standard not applicable
**)
96 dB(µV) ... 50 dB(µV), 10 kHz ... 150 kHz
(Class B)
60 dB(µV) ... 50 dB(µV), 150 kHz ... 350 kHz
50 dB(µV), 0.35 MHz ... 30 MHz
**)
120 dB(µV) ... 69 dB(µV), 10 kHz ... 150 kHz
(Class A)
79 dB(µV), 150 kHz ... 500 kHz
73 dB(µV), 0.5 MHz ... 30 MHz