Graco XM PFP Setup & Operation page 94

Plural-component sprayer
Hide thumbs Also See for XM PFP:
Table of Contents

Advertisement

Appendix B - Alarms
Alarm
Code
Alarm Problem
R5BE
Dosing Sizes Are Not
Optimized.
R5DX
Uncalibrated system in
Weight Mode
R9BE
System detected five R4BF
(Ratio High B) or five R1BF
(Ratio Low B) alarms within
five minutes. Sprayer shuts
down for five minutes for
operator to resolve problem.
*T2DA
Temperature Exceeded
*T2DB
Advisory Limits.
T3CA
A/B Material Heater
T3CB
Temperature Control
Module Over Temperature
Advisory
T3CH
Hose Heater Temperature
Control Module Over
Temperature Advisory
T4CA
A/B Material Heater
T4CB
Temperature Control
Module Over Temperature
Alarm
T4CH
Hose Heater Temperature
Control Module Over
Temperature Alarm
T4CX
Temperature Over
Temperature Switch
T4DA
A/B Material Heater High
T4DB
Temperature RTD 1 Alarm
T4DE
Hose High Temperature
RTD 1 Alarm
T4DH
Hose Heater High
Temperature RTD 2 Alarm
94
When
Active
Cause
Spray
Dosing valve is operating near high
or low timing limits.
Spray
System was not calibrated.
Spray
See R4BE or R1BE alarm causes.
Spray
Fluid temperature exceeded high
or low limits for more than four
minutes.
Always
Module is bad.
Always
Module is bad.
Always
Module is bad.
Always
Module is bad.
Always
Over temperature switch jumper
unplugged.
Always
Heater bad.
RTD bad.
Always
Heater bad.
Splitter cable bad.
RTD bad in hose bundle.
Always
Heater bad.
Splitter cable bad.
RTD bad in hose heater outlet.
Solution
Balance A and B fluid hoses. See
XM PFP Mix Manifold manual.
Or change 'B' restriction. Check
Restriction screen.
Run the Pump and Metering Test
and Calibration for Ratio by
Weight Mode, page 48, and Batch
Dispense or Ratio Test, page 50
to calibrate system for weight
mode. Run system in volume
mode.
Run system in volume mode.
See R4BE or R1BE alarm
solutions. Flush mixed material if
necessary, and purge off-ratio
mixed material in hose.
Same as T5DA or T5DB.
Replace module.
Cool system down.
Replace module.
Cool system down.
Replace module.
Cool system down.
Replace module.
Cool system down.
Replace jumper.
Repair heater.
Replace RTD.
Repair heater.
Replace splitter cable
Replace RTD in hose bundle.
Repair heater.
Replace splitter cable
Replace RTD in hose water heater
outlet.
3A2776K

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

24w626262869262945262943

Table of Contents