Appendix B - Alarms
Alarm
Code
Alarm Problem
CACT
Temperature Control
Module Loss of
Communication
DAAX
Pump Runaway; Above 80
DABX
CPM For 10 Sec.
DDAX
Pump Cavitation; Dives
DDBX
More Than 1/2 Of Stroke.
DEAX
Pump Does Not Move In 10
DEBX
Minutes.
DFAX
Pump Did Not Stall Against
DFBX
Fluid Pressure On Up Stroke
Only.
DGAX
Pump Did Not Stall Against
DGBX
Fluid Pressure On Down
Stroke Only.
DJAX
Pump Motor Linear Sensor
DJBX
Has No Signal.
Pump Motor Linear Sensor
Is Out Of Range.
DKAX
Pump Motor Reed Switch
DKBX
Failure; Missing Signals
From One Or Both Switches.
90
When
Active
Cause
Always
Network communication cable is
bad.
Always
No material in pump or lines; no
fluid restriction.
Spray
No fluid or valve closed.
Material is too cold or thick.
Pump inlet check valve not closing.
Feed pump not providing material.
Inlet strainer plugged (if used).
Park or
Recirculation valves were not
Pump
opened to allow flow.
Test
Pump
Pump piston check valve, piston
Test
packings, or dosing valve are not
holding fluid pressure.
Pump
Pump inlet check or dose valve is
Test
fouled, or damaged.
Always
No linear sensor signal from motor.
Linear sensor plugged in while
power is on.
Bad connection inside fluid control
module.
Always
Linear sensor is beyond range.
Sprayer is not properly grounded.
Always
Bad motor cable connections, or
bad reed switch.
Reed switch cable is plugged in
while power is on.
Bad connection inside fluid control
module.
Solution
Check cable connections.
Refill material in tank or hoses;
install fluid tip.
Refill supply and open inlet valve.
Increase material temperature to
reduce viscosity. See Spray, page
40. Shear material with agitation to
reduce viscosity.
Clear debris from check valve. Or
replace ball, seat, and seal.
Check feed pump (if used).
Check and clean strainer. See XM
PFP repair manual.
Open recirculation valves.
Flush pump. See General Tips,
page 62. Recheck. Remove, clean,
and repair lower. See XM PFP
repair manual.
Remove inlet housing & clean and
inspect. See XM PFP repair
manual.
Swap A and B sensors. Replace
sensor if problem follows sensor.
See XM PFP repair manual.
Power sprayer off and back on. Do
not plug in linear sensor while
power is on.
Replace fluid control module. See
XM PFP repair manual.
Replace sensor or sensor magnet.
See XM PFP repair manual.
See Grounding, page 19.
Swap A and B motor cables.
Replace cable if problem persists.
Otherwise replace reed sensor
assembly. See XM PFP repair
manual.
Power sprayer off and back on. Do
not plug in reed switch cable while
power is on.
Replace fluid control module.
3A2776K