Graco XM PFP Setup & Operation page 41

Plural-component sprayer
Hide thumbs Also See for XM PFP:
Table of Contents

Advertisement

9. Open recirculation valves.
10. Ensure metering pump air regulator (CD) is turned
counterclockwise to 0 psi.
For hazardous location models, do not turn off the main
power switch (CA). If air is blocked, turned off, or
depressurized the system will turn off. To turn on
system, open the main power switch (CA) and allow the
3 minute purge sequence to complete.
CA
11. At the main run (fluid control) screen, press
enter manual pump run mode.
12. Press
repeatedly to select
begin circulating.
NOTICE
Run metering pump as slowly as possible until it is
fully primed to prevent pump damage due to pump
cavitation.
3A2776K
13. Use metering pump air regulator (CD) to slowly
For Hazardous Location Models: the system on/off valve
is already open.
CA
14. Turn A and B tank fluid heater (BB) ON if it isn't
CD
to
15. To adjust tank fluid heater temperature, adjust the
16. Turn on the primary material heaters.
. Press
to
increase the air pressure to the metering pumps
until the enabled pump(s) begin running slowly.
already ON.
BB
numbered knob on the heater.
a. Navigate to the Supply screen. See Operator
Command Mode Screens on page 75.
b. Press
and
primary heaters, and press
hose bundle heater.
Spray
CD
ti26689a
Non-Hazardous
Location
BB
Hazardous
Location
to turn on the A and B
to turn on the
41