Graco XM PFP Setup & Operation page 92

Plural-component sprayer
Hide thumbs Also See for XM PFP:
Table of Contents

Advertisement

Appendix B - Alarms
Alarm
Code
Alarm Problem
*MEA
Maintain Dosing Valve.
X
*MEB
X
*MGP
Maintain Air Filter.
X
P1AX
Pressure Low.
P1BX
*P2AX
Pressure Exceeded
*P2BX
Advisory Limits.
P4AX
Pressure High.
P4BX
P4RE
Pressure High.
P5RE
Pressure High.
*P5AX
Pressure Exceeded Alarm
*P5BX
Limits.
P6AX
Pressure Sensor Failure; No
P6BX
Signal.
P9AX
A Pump Pressure is
Abnormally Low Compared
to B Pump Pressure.
P9BX
B Pump Pressure is
Abnormally Low Compared
to A Pump Pressure.
92
When
Active
Always, if
Dosing valve usage exceeds
enabled
user-set limit. Maintenance due.
Always, if
Air filter exceeds user-set limit.
enabled
Maintenance due.
Spray,
Fluid pressure is below 1000 psi (7
Pump
MPa, 70 bar) for spray mode or
Test, Leak
below 1500 psi (10.3 MPa, 103
Test
bar) to test modes.
Spray
Pressure exceeded high or low
advisory limits for more than 15
seconds.
Always
Fluid pressure is above maximum.
Recirculati
Pressure is above maximum
on
advisory limit of 3000 psi (21 MPa,
210 bar) on A side.
Recirculati
Pressure is above maximum
on
warning limit of 5200 psi (35.9
MPa, 359 bar) on A side.
Spray
Pressure exceeded high or low
alarm limits for more than 15
seconds.
Always
Pressure sensor or cable is bad on
the side indicated.
Spray
A air motor is icing causing
restriction and lower fluid pressure.
A pump is binding.
A motor is binding.
Spray
B air motor is icing causing
restriction and lower fluid pressure.
B pump is binding.
B air motor is binding.
Cause
Service dosing valve. See pump
manual listed on page 4.
Service main air filter and control
filter regulator.
Increase main air regulator.
Same as P5AX or P5BX.
Decrease main air regulator.
Decrease pump air regulator
pressure.
Decrease pump air regulator
pressure.
Adjust pump pressure regulator,
change tips, or adjust target set
point.
Replace sensor and cable
assembly. See XM PFP repair
manual.
Open the air motor de-ice bleed air
controls. Allow ice to melt. Dry
compressed air. Heat compressed
air.
Use a smaller tip.
Repair lower. See XM PFP repair
manual.
Repair air motor. See XM PFP
repair manual.
Open the air motor de-ice bleed air
controls. Allow ice to melt. Dry
compressed air. Heat compressed
air.
Use a smaller tip.
Repair lower. See XM PFP repair
manual.
Repair air motor. See XM PFP
repair manual.
Solution