Supply Screen
Use these screens to turn on and off automatic tank
filling, turn on and off the fluid heaters and hose heat,
and change temperature setpoints for each fluid heater
and for the hose heat.
When automatic tank filling is on, the feed pump will
begin pumping fluid into the tank when the fluid level
goes below the bottom arrow. It will continue filling until
the fluid level reaches the upper arrow. When the feed
pump is running, the small circle on the screen next to
the tank will have a black background. In order for
automatic tank filling to run, the director valve (3DC)
must be in the DOWN position, and the RAM slider
valve (DA) and air motor slider valve (DF) must both be
in the ON position with proper air pressure air supplied
to the RAM and air motor. See Feed Pump Air
Controls on page 14.
3A2776K
Appendix A - User Interface Display
This screen also displays the current volume of each
tank and the current temperature measured at each fluid
heater, at the hoses, and in each tank.
Icon
Function
Turn on and off automatic tank filling
Turn on and off the A fluid heater
Turn on and off the B fluid heater
Turn on and off the hose heat
Press
to three times display additional information.
Additional Information
1
Tank level sensor A (volts)
2
Tank level sensor B (volts)
3
Water/glycol mixture temperature at heater
1
2
3
83