Section 9. Trouble-Shooting

The following are a few suggestions on how to perform a basic troubleshooting, if the emulator does not
respond to the user's commands.
Symptoms
Cannot link to
PC
Cannot
run
code on target
Checks
Expected Observation & Action
Power Supply
POWER LED lights up in Red.
PC Bios setup
USB must be enabled
Window Device
USB do not have any contention. Compact Emulator
Manager
must be detected instead of a USB device.
Standalone Self
POWER LED lights up in Orange denoting entering self
Test
test mode
Adjacent RUN LED do not light up after the test,
Blinking POWER LED
USB cable and
Clean the contact.
connector contacts
Change the USB cable.
Target System
Is user supply provided to the target?
HEW Setup
Has HEW been setup in the PC?
Clock setting
Is clock set to "target"?
Is there any clock signal input to the emulator?
Mode setting
Is mode set to "target"?
Reset setting
Is reset masked in the HEW configuration platform
window?
STBY setting
Is STBY masked in the HEW configuration platform
window?
NMI
Is NMI masked in the HEW configuration platform
window?
Power Supply
Is Target supplying power to the emulator?
Cable detection
Has HEW detected the Cable?
Is CABLE_IN_N tied to ground in the target system?
Target connection
Is the target connection tight and secure?
Signal level
Is the emulator pull-up resistors driving the target
system?