[Pr. PD60_DI pin polarity selection (*DIP)]

Initial value
00000000h
For DI pin numbers corresponding to setting digits, refer to the following table.
If this servo parameter is set incorrectly, [AL. 037 Parameter error] may occur.
Servo parameter number
[Pr. PD60.0]
[Pr. PD60.0_DI pin polarity selection]
Initial value
0h
Select the DI pin polarity.
Setting digit (BIN)
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
[Pr. PD60.1_For manufacturer setting]
This servo parameter is for manufacturer setting.
[Pr. PD60.2_For manufacturer setting]
This servo parameter is for manufacturer setting.
[Pr. PD60.3_For manufacturer setting]
This servo parameter is for manufacturer setting.
[Pr. PD60.4_For manufacturer setting]
This servo parameter is for manufacturer setting.
[Pr. PD60.5_For manufacturer setting]
This servo parameter is for manufacturer setting.
[Pr. PD60.6_For manufacturer setting]
This servo parameter is for manufacturer setting.
[Pr. PD60.7_For manufacturer setting]
This servo parameter is for manufacturer setting.
1 SERVO PARAMETER DETAILS
76
1.5 I/O setting servo parameters group ([Pr. PD_ _ ])
Setting range
Refer to the relevant detail No.
Setting digit (BIN)
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
Setting range
Refer to the text
Ver.
Refer to the relevant detail No.
Name
DI pin polarity selection 1
DI pin polarity selection 2
DI pin polarity selection 3
For manufacturer setting
Ver.
A4
Function
DI pin polarity selection 1
0: ON with 24 V input
1: ON with 0 V input
DI pin polarity selection 2
0: ON with 24 V input
1: ON with 0 V input
DI pin polarity selection 3
0: ON with 24 V input
1: ON with 0 V input
Model
CN3-2
CN3-12
CN3-19