[Pr. PC79.1_DI status read selection]
Initial value
00h
Select whether to return the on/off state of the input device or the on/off state of the pin when reading [Digital inputs (Obj.
60FDh)].
Setting digit (BIN)
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
Setting range
Refer to the text
Function
EM2/EM1 status read selection
Select the EM2/EM1 (bit 22) status read operation.
For the DI pin corresponding to EM2/EM1, refer to the following table.
0: Returns the on/off state of the input device.
1: Returns the on/off state of EM2/EM1 pin.