[Pr. PC06_Function selection C-3 (*COP3)]

Initial value
00000000h
[Pr. PC06.0_In-position range unit selection]
Initial value
0h
Select a unit of the in-position range.
This servo parameter is enabled only in the position mode.
0: Command input pulse unit
1: Servo motor encoder pulse unit
[Pr. PC06.3_Excessive error alarm trigger level/excessive error warning trigger level -
Unit selection]
Initial value
0h
Select the unit used when setting the excessive error alarm trigger level in [Pr. PC01 Excessive error alarm trigger level] and
setting the excessive error warning trigger level in [Pr. PC38 Excessive error warning trigger level].
This servo parameter is enabled only in the position mode.
0: [rev] or [mm]
1: [0.1 rev] or [0.1 mm]
2: [0.01 rev] or [0.01 mm]
3: [0.001 rev] or [0.001 mm]

[Pr. PC07_Zero speed (ZSP)]

Initial value
50 [r/min], [mm/s]
Set an output range of the zero speed signal (ZSP).
The zero speed signal detection has a hysteresis of 20 [r/min] (20 [mm/s]).

[Pr. PC08_Overspeed alarm detection level (OSL)]

Initial value
0 [r/min], [mm/s]
Set an overspeed alarm detection level.
When a value exceeding "servo motor maximum speed × 120 %" is set, the value will be clamped at "servo motor maximum
speed × 120 %".
When "0" is set, the value of "servo motor maximum speed × 120 %" will be set.

[Pr. PC17_Function selection C-4 (**COP4)]

Initial value
00000000h
[Pr. PC17.1_Linear encoder multipoint Z-phase input - Function selection]
Initial value
0h
When multiple reference marks exist during the full stroke of the linear encoder, set "1".
0: Disabled
1: Enabled
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
Setting range
Refer to the text
Setting range
0 to 10000
Setting range
0 to 20000
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
1.4 Extension setting servo parameters group ([Pr. PC_ _ ])
Ver.
Refer to the relevant detail No.
Ver.
A4
Ver.
A4
Ver.
A4
Ver.
A4
Ver.
Refer to the relevant detail No.
Ver.
B2